A novel current injection network for low-harmonic rectifiers that apply the third harmonic current injection is proposed in this paper. The current injection network requires one inductor, two capacitors, and one 1:1 transformer with a voltampere rating of only 0.16% of the input power. The transformer is introduced to provide complete rejection of harmonic components of the injected currents at even triples of the line frequency, resulting in significant reduction of the input current total harmonic distortion (THD). Dependence of the input current THD on the current injection network Q factor is computed. The THD is shown to be in the range 4%>THD>5.125%. Analytically obtained results are experimentally verified on a 1.5 kW rectifier.
机译:提出了一种新颖的低谐波整流器电流注入网络,该网络应用了三次谐波电流注入。电流注入网络需要一个电感器,两个电容器和一个1:1变压器,其额定伏安仅为输入功率的0.16%。引入该变压器是为了在输入频率的三倍频率下完全抑制注入电流的谐波分量,从而显着降低输入电流的总谐波失真(THD)。计算输入电流THD对电流注入网络Q因子的依赖性。显示的THD在4%> THD> 5.125%的范围内。分析获得的结果在1.5 kW整流器上进行了实验验证。