首页> 外文会议>IFAC Symposium on Modeling and Control in Biomedical Systems >ISOMETRIC MUSCLE CONTRACTION INDUCED BY REPETITIVE PERIPHERAL MAGNETIC STIMULATION
【24h】

ISOMETRIC MUSCLE CONTRACTION INDUCED BY REPETITIVE PERIPHERAL MAGNETIC STIMULATION

机译:通过重复外周磁刺激引起的等距肌肉收缩

获取原文

摘要

Repetitive peripheral magnetic stimulation (RPMS) is an innovative approach in treatment of central paresis, e.g. after stroke, by inducing muscle contractions and relaxations. The therapeutic effect can be increased by a closed loop control to induce coordinated movements in the forearm and the fingers. An appropriate model of muscle contractions induced by RPMS provides the basis for the controler design. In the presented paper a model based on a Hammerstein-structure for the contraction of the biceps brachii will be established. This model also builds the basis for a nonlinear system identification which is used to individualize the model to a single subject.
机译:重复外周磁刺激(RPMS)是一种治疗中央自皮的一种创新方法,例如,中风后,通过诱导肌肉收缩和放松。通过闭环控制可以增加治疗效果,以诱导前臂和手指的协调运动。 RPM诱导的肌肉收缩模型为控制器设计提供了基础。在本文中,将建立基于Hammerstein结构的模型,以便将BIENSPS Brachii收缩。该模型还构建了非线性系统标识的基础,该基础用于将模型单独化为单个主题。