Already existing knowledge about aging phenomenon in type insulated power cables as well as measuring criteria has been continuously improved during last 20-30 years. Nowadays many HV power circuit with paper insulation reach their end of service life time due to extensive deterioration of insulation under high operational temperatures and electrical, mechanical overstressing. Growing demand of energy market for new sources of energy and increment of current loads on existing serviced HV power transmission cables change aging rates and lead to often unexpected failures. Accelerate in this way insulation deterioration processes in many cases need new interpretation of diagnostic parameters related to aging of cable insulation to support condition assessment decision and foreseen failure development. Additionally when costs of repairs, cable replacement and customer claims due to breakdown and blackouts are taken into consideration, finance balance for the repair of a single failure in a 150kV link can costs around 75kC [3]. For this reason reliable judgment of actual cable condition with available on market diagnostic methods is in great of importance from utility point of view. In this contribution effort was put to estimate actual service condition of four sections of external gas pressure 110kV-150kV power cables with two integral diagnostic methods. Interpretation of diagnostic data has been done with aspect to several diagnostic parameters. All relevant diagnostic parameters were obtained during on-site tests in with low-voltage method based on recovery voltage phenomena and high voltage method based in DAC voltages to estimated dielectric losses.
机译:已有大约型绝缘电力电缆老化现象,以及衡量的标准已经在过去的20 - 30年不断完善知识。时下纸绝缘许多HV电力电路达到其使用寿命的结束时,由于在高操作温度和电气,机械超绝缘的广泛退化。对现有服务高压输电电缆的能量和电流负载的增加的新来源能源市场的不断增长的需求的变化老化率,导致经常意外故障。加快在许多情况下,这种方式绝缘老化过程需要涉及到电缆绝缘老化支持状态评估决定的和可预见的故障诊断的发展参数的新诠释。此外,当修理,更换电缆和客户要求由于击穿和停电的成本考虑,在一个的150kV链接为单个故障的修复融资余额可围绕75kC [3]成本。对于电缆的实际情况与现有市场上的诊断方法,因此可靠的判断是伟大但从实用角度的重要性。在这种贡献的努力付诸估算外部气压的110kV-的150kV电力电缆的四个部分实际使用情况与两个整体诊断方法。诊断数据的解释已完成方面的几个诊断参数。期间在现场试验在具有低电压法根据基于在DAC电压估计介电损耗恢复电压现象和高压方法获得的所有相关的诊断参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号