In this study a water soluble polymer, poly(vinyl pyrrolidinone) (PVP), was used for separation and preconcentration of Hg(Ⅱ) prior to their analysis by Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES). Poly(vinyl pyrrolidinone) polymers containing a pendant lactam ring which is part of a monomeric repeat unit structure can form complexes with target metal ions via oxygen and nitrogen. The Hg(Ⅱ) and polymer solution were mixed and Hg(Ⅱ)-bound polymer was precipitated upon addition of acetone. Adding saturated KNO3 solution to the sample, by the salting out effect, causes the precipitation to be completed faster with less amount of acetone. The precipitate was separated from the solution and dissolved directly with ultra deionised water. In this way, analyte elements were again transferred into the liquid phase and analysed by ICP-AES. The effects of pH, amount of the polymer, molecular weight of the polymer, Hg(Ⅱ) ion concentration and centrifuging time on the recovery of the target metal ion have been investigated. The equilibrium experimental data were fitted to Langmuir and Freundlich isotherms models. The maximum Hg(Ⅱ) adsorption capacity from aqueous solutions obtained was 30.4 mg/g at pH of about pH 6.0. Adsorption of heavy metal ions from artificial waste water was also studied. The adsorption capacities were 26.5 mg/g for Hg(Ⅱ), 20.2 mg/g for Cd(Ⅱ) and 15.3 mg/g for Pb(Ⅱ) with recoveries greater than 97% and relative standard deviations of lower than 3% n=5.
机译:在该研究中,在通过电感偶联的等离子体原子发射光谱(ICP-AES)分析之前,使用水溶性聚合物,聚(乙烯基吡咯烷酮)(PVP)进行HG(Ⅱ)的分离和前浓缩。聚(乙烯基吡咯烷酮)含有侧酰胺内酰胺环的聚合物,其是单体重复单元结构的一部分可以通过氧和氮与靶金属离子形成复合物。将Hg(Ⅱ)和聚合物溶液混合,加入丙酮后沉淀Hg(Ⅱ)沉淀。通过盐析效果将饱和的KNO3溶液加入样品中,使沉淀更快地完成,含量较少的丙酮。将沉淀物与溶液分离并直接用超去离子水溶解。以这种方式,分析物元素再次转移到液相中并通过ICP-AES分析。研究了pH,聚合物的量,聚合物的分子量,Hg(Ⅱ)离子浓度和离心时间对靶金属离子的回收率的影响。均衡实验数据适用于Langmuir和Freundlich等温机构。所得水溶液的最大Hg(Ⅱ)吸附容量为30.4mg / g在pH值约为pH6.0。还研究了从人造废水中的重金属离子的吸附。 Hg(Ⅱ)的吸附容量为26.5mg / g,用于CD(Ⅱ)的20.2mg / g,Pb(Ⅱ)的15.3mg / g,回收率大于97%,相对标准偏差低于3%n = 5。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号