首页> 外文会议>International Conference on Solid-State and Integrated-Circuit Technology >Design and test results of a front-end ASIC for radiation detectors
【24h】

Design and test results of a front-end ASIC for radiation detectors

机译:用于辐射探测器的前端ASIC的设计和测试结果

获取原文
获取外文期刊封面目录资料

摘要

A front-end ASIC for semiconductor radiation detectors is presented. It is composed of a Charge Sensitive Amplifier (CSA), a pulse shaper, and a Peak Detect and Hold (PDH) circuit. Poly-resistor is used as source degeneration component to reduce the noise of current source in the CSA. The ASIC has been designed in a 0.5um CMOS DPTM technology and tested with Verigy 93000. The gain (PDH excluded) is 78.5mV/fC and the Equivalent Noise Charge (ENC) with detector disconnected is 800–900e. The power dissipation without the output buffer is about 2.6mW.
机译:提出了一种用于半导体辐射探测器的前端ASIC。它由充电敏感放大器(CSA),脉冲整形器和峰值检测和保持(PDH)电路组成。多电阻器用作源退化组件,以减少CSA中电流源的噪声。 ASIC已设计成0.5UM CMOS DPTM技术,并用VERIGY 93000进行测试。增益(不包括PDH)为78.5mV / Fc,探测器断开的等效噪声充电(ENC)为800-900E。没有输出缓冲器的功耗约为2.6mW。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号