Georgia Power Plant Hammond Scrubber Performance Decline

机译:格鲁吉亚电厂Hammond洗涤器性能下降

获取原文

摘要

The Flue Gas Desulfurization (FGD) system at Georgia Power Plant Hammond suffered a reduction in performance in 2010. Optimal FGD performance is increasingly important because all four generating units on the site will rely on the scrubber for mercury control, acid gas removal and particulate reduction for compliance with the new MACT rule. This paper describes how the performance shortfall was detected and corrected, what was the root cause of the problem, what steps are being taken to avoid a reoccurrence, what on-line monitoring measures are being employed to verify healthy FGD performance and what methods could be used while the FGD system remains in service to correct a similar problem. The methods described include remote monitoring and diagnostics using FGD performance models, infrared thermography surveys, additional instrumentation and mechanical equipment.
机译:格鲁吉亚发电厂哈蒙德的烟气脱硫(FGD)系统在2010年遭受了绩效的减少。最佳的FGD性能越来越重要,因为该网站上的所有四个发电机将依靠汞控制的洗涤器,酸性气体去除和颗粒状遵守新的执行规则。本文介绍了如何检测和纠正性能缺口,问题的根本原因是什么,避免再次进行的步骤,正在采用哪些在线监测措施来验证健康的FGD性能以及哪些方法可以在FGD系统仍在使用时使用以纠正类似的问题。所描述的方法包括使用FGD性能模型,红外热成像调查,附加仪器和机械设备进行远程监控和诊断。