The paper will discuss the Circulating Fluidized Bed (CFB) Scrubber System installed at Public Power Generation Agency's (PPGA's) Whelan Energy Center Unit 2 (WEC2) in Hastings, Nebraska. The design of the CFB Scrubber System, including scalping electrostatic precipitator (ESP), reagent preparation system, CFB absorber, pulse jet fabric filter (PJFF), and ash handling system will be reviewed. Results of the initial emissions compliance test will be presented, as well as ongoing emissions data collected by the Continuous Emissions Monitoring System (CEMS). Operational requirements will be discussed, including normal daily operational requirements, operational limitations, and operational issues that have been faced by plant operating personnel. The maintenance requirements of the CFB Scrubber System will be discussed, including maintenance schedules and manpower requirements. Plant modifications that were made to address operational issues implemented during plant startup will be described. Finally, recommendations will be made for consideration in future designs.
机译:本文将讨论在黑斯布拉斯加州的公共发电代理(PPGA)Whelan Energy Center 2(WEC2)上安装的循环流化床(CFB)洗涤器系统。 CFB洗涤器系统的设计,包括脱脂静电除尘器(ESP),试剂制备系统,CFB吸收剂,脉冲射流织物过滤器(PJFF)和灰处理系统。初始排放量测试的结果将出现,以及连续排放监测系统(CEM)收集的正在进行的排放数据。将讨论运营要求,包括植物操作人员面临的正常日常业务要求,运营限制和运营问题。将讨论CFB洗涤系统的维护要求,包括维护时间表和人力要求。将描述为解决工厂启动期间实施的运营问题的植物修改。最后,将在未来的设计中考虑建议。