首页> 外文会议>European Conferenc of the International Federation for Medical and Biological Engineering >The Influence of Inter-Crystal Scattering on Detection Efficiency of Dedicated Breast Gamma Camera: A Monte Carlo Study
【24h】

The Influence of Inter-Crystal Scattering on Detection Efficiency of Dedicated Breast Gamma Camera: A Monte Carlo Study

机译:间晶体散射对专用乳房伽玛相机检测效率的影响:蒙特卡罗研究

获取原文

摘要

Dedicated gamma cameras based on Photodiodes coupled to pixellated small size scintillators, is suitable for high resolution imaging such as small animal and breast cancer imaging. It is well known that inter-crystal scattering (ICS) is of the major resolution degradation factors in the system with small crystal size. The aim of this study is to quantitatively calculate the ICS events in different types of crystal material (CsI, NaI and LaBr3) and size (0.5x0.5, 1x1, 1.5x1.5 and 3x3 mm~2) using Monte Carlo simulation. The simulations were designed to optimize camera design particularly for crystal pixel size and scintillation material. Three types of scintillation crystal were exposed by 140 keV photons of a point source as a pencil beam in orthogonal and oblique incidences. In oblique incidence, detected events in central pixel of crystal array decreased in small angles slowly and then decreased rapidly by increasing of incidence angle. In orthogonal incidence in four different pixel sizes, the percentage of photons encounters the ICS event in CsI crystal was 1.82%, 3.76%, 4.94% and 6.49% events for 3x3, 1.5x1.5, lxl and 0.5x0.5 mm2 crystal pixel size respectively, that were less than NaI and LaBr3 crystals. Also in the oblique incidence, in all pixel sizes of CsI crystal the photons encountered ICS events were less than NaI and LaBr3. According to our results, The CsI crystal from the point of view of higher detection efficiency and position detection accuracy (PDA) and lower ICS is preferable. However, the optimal crystal material and size for high resolution breast imaging are still open questions which require further research and development efforts.
机译:基于光电二极管专用伽马照相机耦合到像素化小尺寸的闪烁器,适合于高分辨率成像诸如小动物和乳腺癌成像。它公知的是晶间散射(ICS)是在具有小晶体尺寸的系统的主要分辨率下降的因素。本研究的目的是定量地计算在利用蒙特卡罗模拟不同类型的液晶材料(CSI,碘化钠和LaBr3)和大小(0.5x0.5,1x1的,1.5x1.5和3x3毫米〜2)的ICS的事件。该模拟物设计为优化相机设计特别是对于晶体像素大小和闪烁材料。三种类型的闪烁晶体的通过点源在正交和倾斜发生率笔形射束的140keV的光子露出。在斜入射,在晶体阵列的中心像素检测到的事件在小角度慢慢下降,然后通过入射角的增大迅速减小。在四种不同的像素尺寸垂直入射角,光子的百分比在遇到的CsI晶体中的ICS的事件是1.82%,3.76%,3×3,1.5x1.5,1×1和0.5x0.5 mm2的晶​​体像素4.94%和6.49%的事件大小分别,即小于的NaI和LaBr3晶体。另外,在倾斜入射,在晶体的CsI的所有像素尺寸的光子遇到ICS事件是小于的NaI和LaBr3。根据我们的结果,从更高的检测效率和位置检测精度(PDA)的点所述CSI晶体并降低ICS是优选的。然而,对于高分辨率乳腺成像的最佳晶体材料和尺寸仍需要进一步的研究和开发工作开放性问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号