首页> 外文会议>Euro-Asian Pulsed Power Conference >Experimental Studies on Charging Operation of a Compact Repetitive Tesla Transformer
【24h】

Experimental Studies on Charging Operation of a Compact Repetitive Tesla Transformer

机译:紧凑型重复特斯拉变压器充电运行的实验研究

获取原文

摘要

Charging operations of a compact Tesla transformer were experimentally investigated, in single-shot and rep-rate (50pps for 1s) modes, respectively. The charging limitations were also explored. The experimental results were compared and analyzed. The maximum secondary charging voltages of the Tesla transformer were measured to be 380kV and 300kV in single-shot and rep-rate modes, respectively. The RMS pulse-to-pulse instability of the secondary charging voltage is generally less than 10% but increases with the increasing initial voltage across the primary capacitor. Since the secondary capacitor of the Tesla transformer is a pulse forming line (PFL), continued operation is possible if there is breakdown in the PFL. Furthermore, operation can even be continued under occasional breakdown for some pulses, without the effects on the operations of subsequent pulses.
机译:专利地研究了紧凑型特斯拉变压器的充电操作,分别以单次和批量(50pps为1S)模式进行实验研究。还探讨了充电限制。比较和分析实验结果。分别测量TESLA变压器的最大二次充电电压分别为380kV和300kV,分别在单次和REP率模式中。二次充电电压的RMS脉冲到脉冲稳定性通常小于10%,但随着初级电容器上的初始电压的增加而增加。由于特斯拉变压器的次级电容器是脉冲形成线(PFL),因此如果PFL中存在故障,则可以继续操作。此外,甚至可以在某些脉冲次突破的情况下继续操作,而不会对后续脉冲的操作的影响。