pH MEASUREMENT CAPABILITY THROUGH THE PRIMARY pH MEASUREMENT OF CARBONATE BUFFER SOLUTION

机译:通过碳酸酯缓冲溶液的一次pH测量来测量能力

获取原文

摘要

The Chemical Metrology Division (Dquim) from National Institute of Metrology, Standardization and Industrial Quality - Inmetro established in 2003 the primary system of pH measurement. The main use of this system is to provide reliability and traceability to the pH measurements in Brazil since its measurement is one of the most important analyses carried out in many laboratories all over the country. In order to show comparability and capability in primary pH measurement, Inmetro participated in both the key-comparisons CCQM-K18 and in the supplementary comparison that followed, named CCQM-K18.1, to measure the pH in a carbonate buffer solution of nominal value of pH 10.01. The event was organized by Consultative Committee for Amount of Substance (CCQM) of BIPM. This work aimed at showing the development and optimization of the primary pH system from INMETRO in order to participate in this key-comparison, which was considered successful because of the high performance obtained by Inmetro in that supplementary comparison.
机译:来自国家计量研究所,标准化和工业质量研究所的化学计量司(DQUIM) - 2003年成立的MP测量初级系统。该系统的主要用途是为巴西的PH测量提供可靠性和可追溯性,因为它的测量是全国各地的许多实验室中的最重要分析之一。为了显示初级pH测量中的可比性和能力,在关键 - 比较CCQM-K18和随​​后的补充比较中参与了CCQM-K18.1的补充比较,以测量标称值的碳酸盐缓冲液中的pH值pH 10.01。该活动由BIPM的物质咨询委员会组织。这项工作旨在表明来自Inmentro的初级pH系统的开发和优化,以便参与该键 - 比较,这被认为是成功的,因为通过该补充比较中的成品获得的高性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号