Electrochemical Migration has been discovered on your assembly after burn-in, or worse yet, on a product returned from the field. A leakage current developed between two isolated circuits and a short circuit occurred. You build IPC Class 2, Dedicated Service Electronic, and Class 3, High Performance Electronic, Products, so this type of failure is of great concern to your company. You want to know if this is an isolated incident or is your whole lot in danger of failing in the field? This article outlines options that are available to analyze this specific lot of assemblies and steps that can be taken to prevent ECM failures on future lots. IPC J-STD-001, Requirements for Soldered Electrical and Electronic Assemblies, is used as a guideline in preparing a customized test procedure. This article outlines exact procedures that may be used to assess non-failed assemblies for ECM potential. Case studies are included. The general procedure is as follows: Monitoring points connected to the area of concern are isolated, often by removing components or cutting other traces and wires are soldered. The assemblies are placed in a temperature/humidity chamber and a bias is applied across the suspect location. The resistance between these isolated points is monitored for sudden or slow drops that are indicative of leakage current development or dendritic growth. If ECM development is observed on these assemblies from the same lot, the entire lot should be considered at risk.
机译:在烧毁或更糟糕的情况下,在从场上返回的产品中,您的装配中发现了电化学迁移。发生在两个隔离电路和短路之间产生的漏电流。您构建IPC类2,专用服务电子和3级,高性能电子,产品,所以这种故障对贵公司非常关注。你想知道这是否是一个孤立的事件,或者你的整个危险失败了吗?本文概述了分析此特定大量装配和步骤的选项,以防止ECM对未来批次的故障。 IPC J-STD-001,焊接电气和电子组件的要求,用作准备定制测试程序的指导。本文概述了可用于评估ECM潜力的非失败组件的确切程序。包括案例研究。通用程序如下:通过去除组件或切割其他迹线和焊接电线而被隔离连接到关注区域的监测点。将组件放置在温度/湿度室中,并且在嫌疑人位置施加偏压。监测这些分离点之间的电阻,用于突然或缓慢的液滴,其指示漏电流发育或树突生长。如果在这些组件上观察到ECM开发,则应考虑危险的整个批次。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号