Industrial load modeling is very important because it enables a power system engineer to determine the status of power system when subjected to gradual or sudden disturbances. This paper presents the measured electric load characteristics of Magadi Soda Company modeled using static model (ZIP model) and dynamic model (slip model). Simulations are done to compare if these models can capture the power quality effects. The result shows that for all the seven cases of sadden disturbances the load is wholly dynamic and the dynamic model gives very accurate results as compared to static model. The load model structure can also be used to estimate the technical energy losses. Symbols; P=active power, Q=reactive power, V=voltage and ω=angular frequency.
机译:工业载荷建模非常重要,因为它使电力系统工程师能够在逐渐或突然干扰时确定电力系统的状态。本文介绍了使用静态模型(ZIP模型)和动态模型(SLIP模型)建模的Magadi苏打公司的测量电负荷特性。如果这些模型可以捕获电源质量效果,则执行模拟以进行比较。结果表明,对于所有七种悲伤扰动的案例,负载完全是动态的,并且动态模型与静态模型相比提供了非常准确的结果。负载模型结构也可用于估计技术能量损失。符号; P =有功功率,Q =无功功率,V =电压和ω=角频率。