首页> 外文会议>Corrosion Conference and Exposition >Corrosion under insulation - testing of protective systems at high temperatures
【24h】

Corrosion under insulation - testing of protective systems at high temperatures

机译:绝缘下的腐蚀 - 高温保护系统的测试

获取原文

摘要

Corrosion under insulation (CUI) has been a continuous challenge for on- and off-shore installations, requiring continuous focus on maintenance work. Pilot scale accelerated testing has been performed to study and evaluate the effects of CUI on different coating systems and service conditions. A test loop has been constructed, where 115 mm o.d. pipe spools were combined in a loop which is internally heated using steam. The coated and insulated pipe spools were exposed at controlled internal temperatures and intermittently wetted by fresh seawater. Two test lines with 8 pipe spools have been run in parallel.Different aspects of CUI, including methods of steel pretreatment, coating application conditions, coating types and insulation design have been studied. Special focus has been on high temperature service conditions and the effect of moist and intermittently wet condition. High temperature coatings have been compared with a traditional coating system and thermally sprayed aluminum coating. The effect of coating application during service with steel temperatures up to 150°C has been studied.Due to the harsh exposure conditions, both tested coating systems were heavily degraded and a fair comparison of the coating systems is difficult. A positive effect of distance insulation was the most significant result from the test, and both tested coating systems showed markedly improved quality using distance insulation. The different application temperatures showed significant differences, and the results were in general better for the coatings applied at ambient conditions. Only minor differences were observed between the different steel pre-treatment methods.
机译:腐蚀下绝缘(CUI)一直是陆地和海上安装一个持续的挑战,需要持续关注的维修工作。中试规模的加速试验已经进行研究和评估崔对不同的涂料体系和服务条件的影响。测试回路已经构建,其中115毫米O.D.短管合并于其中使用蒸汽从内部加热的循环。将涂布和绝缘管线轴物在受控的内部温度暴露并用新鲜海水间歇润湿。两条测试线与8个短管已经在CUI的parallel.Different方面,包括钢材预处理的方法被运行,涂层的应用条件,涂层类型和绝缘设计进行了研究。特别重点一直放在高温服务条件以及湿润和间歇地湿润的条件下的效果。高温涂层已经用传统的涂布系统和热喷涂铝涂层进行比较。与钢温度高达150℃服役期间涂覆申请的效果已经studied.Due恶劣的曝光条件,这两种测试的涂布系统受到严重劣化和涂料体系的一个公平的比较是困难的。绝缘距离的积极作用是从测试最显著结果,并使用距离绝缘既测试涂层体系显示出显着提高质量。不同的应用温度下表现出显著差异,并且结果是在一般更好的为施加在环境条件下的涂层。不同的钢预处理方法之间仅观察到微小的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号