首页> 外文会议>ASME InterPack Conference >A NOVEL AIRFLOW MANAGEMENT SYSTEM WITH REDUNDANT FAN FIELD REPLACEABLE UNITS
【24h】

A NOVEL AIRFLOW MANAGEMENT SYSTEM WITH REDUNDANT FAN FIELD REPLACEABLE UNITS

机译:一种新型气流管理系统,具有冗余风扇领域可更换单位

获取原文

摘要

A novel airflow architecture for a networking chassis will be described in this work. This chassis is a pull system with two sets of four fans located in series at its exhaust. Each set of four fans is a field replaceable unit (FRU). The unique feature of this chassis is that one set of fans, called the rear fan FRU, is replaceable from the rear side of the chassis and the other set of fans, called the front fan FRU, is replaceable from the front side of the chassis. Computational fluid dynamics simulations and measurement data show this chassis is capable of providing up to 78% - 79% of its maximum cooling capacity when one fan FRU is removed from the chassis, and up to 62% - 67% of its maximum cooling capacity when one fan FRU has failed.
机译:在这项工作中将描述用于网络机箱的新型气流架构。这款底盘是一个拉动系统,有两组四个风扇,位于其排气时串联。每组四个风扇是一个现场更换单元(FRU)。这个机箱的独特特征是,一套称为后风机FRU的风扇可更换底盘的后侧,另一组扇形,称为前扇FRU,可从底盘的前侧更换。计算流体动力学模拟和测量数据显示,当一个风扇FRU从底盘移除时,该底盘的最大冷却能力能够提供高达78% - 79%的最大冷却能力,并且在其最大冷却能力的最大冷却能力的最高达62% - 67%一个粉丝FRU失败了。