This paper has studied the dynamic properties and seismic performance of the Mega tower of China World Trade Center Phase 3A by the shaking table model test. The super-structure of the testing model, consisting of a 74 stories tube-in-tube structure provided by a perimeter composite moment frame, a braced composite central core frame, and two outriggers as means of linkage between the tubes, had a total weight of 500kN and a length scale of 1/30. In the design and fabrication of the test model, the similitude formulas and similitude factors of all physical quantities are studied. The test results are analyzed and simulated in detail with SAP 2000 program. The test and simulation results show that the design scheme of the Mega tower meets the requirements of the three seismic fortification levels specified in the Chinese Code, Code for Seismic Design of Buildings (GB50011-2001), and the dynamic properties of the Mega tower can be simulated well by the testing model.
机译:本文研究了中国世界贸易中心第3A型巨型塔的动态性质和地震性能,摇动台模型试验。测试模型的超结构,由周边复合力矩框架,支撑复合中央芯框架和两个外轴作为管之间的连杆装置提供的74层管 - 管式结构组成。总重量500kN和1/30的长度等级。在测试模型的设计和制造中,研究了所有物理量的类似形式和模拟因素。通过SAP 2000程序详细分析和模拟测试结果。测试和仿真结果表明,Mega Tower的设计方案符合中国代码中规定的三个地震设防水平的要求,建筑物的地震设计规范(GB50011-2001),以及Mega Tower的动态特性通过测试模型模拟很好。