首页> 外文会议>2AESE 2007;International Conference on Advances in Experimental Structural Engineers >SHAKING TABLE MODEL TEST OF THE MEGA TOWER OF CHINA WORLD TRADE CENTER PHASE 3A
【24h】

SHAKING TABLE MODEL TEST OF THE MEGA TOWER OF CHINA WORLD TRADE CENTER PHASE 3A

机译:中国世界贸易中心3A期巨型塔的振动台模型测试

获取原文

摘要

This paper has studied the dynamic properties and seismic performance of the Mega tower of China World Trade Center Phase 3A by the shaking table model test. The super-structure of the testing model, consisting of a 74 stories tube-in-tube structure provided by a perimeter composite moment frame, a braced composite central core frame, and two outriggers as means of linkage between the tubes, had a total weight of 500kN and a length scale of 1/30. In the design and fabrication of the test model, the similitude formulas and similitude factors of all physical quantities are studied. The test results are analyzed and simulated in detail with SAP 2000 program. The test and simulation results show that the design scheme of the Mega tower meets the requirements of the three seismic fortification levels specified in the Chinese Code, Code for Seismic Design of Buildings (GB50011-2001), and the dynamic properties of the Mega tower can be simulated well by the testing model.
机译:本文通过振动台模型试验研究了中国国际贸易中心3A期巨型塔的动力特性和抗震性能。测试模型的上层结构总重为74层,由周长的复合弯矩框架,支撑的复合中心核心框架和两个支腿(作为支管之间的连接装置)提供, 500kN的长度和1/30的长度比例。在测试模型的设计和制作中,研究了所有物理量的相似公式和相似因子。使用SAP 2000程序对测试结果进行了详细分析和模拟。测试和仿真结果表明,该巨型塔的设计方案符合《中国规范》,《建筑抗震设计规范》(GB50011-2001)规定的三个抗震设防级别的要求,并且该巨型塔的动态特性可以满足要求。测试模型可以很好地模拟它。