The performed analysis has demonstrated that in a case of reactor compartment unit sinking accompanied by destruction of both strong hull and reactor installation the annual individual radiation risk due to work at the water area would not exceed 1.10~(-6) corresponding to the level of "negligible risk" according to the Russian Radiation Safety Standards (RSS-99). Individual annual damage expressed in "lost years of life" would not exceed 2.10~(-5) years provided that the time of NS waterborne storage prior to dismantlement would make up 5 years and after dismantlement 0 years (i.e., RU sinking would occur immediately after making up). If applying a more realistic option (10 years of waterborne storage prior to and after dismantlement), the value of this parameter would not exceed 1.10~(-6) years.
机译:所执行的分析表明,在反应堆单元的情况下,伴随着强大的船体和反应堆安装的损坏,由于水域的工作的年度单独的辐射风险不会超过1.10〜( - 6)根据俄罗斯辐射安全标准(RSS-99),“忽略不计风险”。 “生命中失去的年龄”表达的个人年度损害不会超过2.10〜( - 5)年,条件是在拆除前的NS水性储存的时间将占5年和拆除0年后(即RU下沉会立即发生化妆后)。如果应用更现实的选择(在拆除前10年的水上储存),该参数的价值将不会超过1.10〜( - 6)年。