首页> 外文会议>Conference on Photonic Therapeutics and Diagnostics >A comparison of single use and reusable small core sized holmium:YAG laser fibers: Is there a difference in the risk of fiber failure?
【24h】

A comparison of single use and reusable small core sized holmium:YAG laser fibers: Is there a difference in the risk of fiber failure?

机译:单一使用和可重复使用的小核尺寸钬:YAG激光纤维:纤维失效风险有差异吗?

获取原文

摘要

This study tests the hypothesis that repeat steam sterilization will result in an increase in the rate of holmium:YAG laser fiber failure during bench testing in a series of commercially available single use and reusable small core sized (200-272 μm) holmium:YAG laser fibers. Single use and reusable small core-sized holmium laser fibers were tested. Single use fibers included the Dornier Lightguide Super 200, Dornier DUR Laser Fiber Single Use, Optical Integrity Scopesafe 272, IQinc. LLF200TG-D and LLF273TG-D, Boston Scientific AccuFlex 200 and AccuFlex 273, and Lumenis Slimline EZ 200. Reusable fibers included the Dornier DUR Laser Fiber Reusable, Lumenis Slimline 200, Sharplan 200, Laser Peripherals RBLF-200, IQinc. LFT273NT, and Convergent Optiview SMH1020F. A Lumenis VersaPulse 100 watt and a PowerSuite 20 watt holmium:YAG lasers were used. Fibers were bent to 180 degrees at a diameter of 1.5 cm. The laser was fired at 1.5J, 10Hz for 30 minutes or until fiber fracture. Reusable fibers were sterilized for a total of twenty cycles using the manufacturers' specifications and retested after every five completed cycles. No fiber fractured with bending alone. Two of three Dornier Super 200 single use fibers fractured repeatedly within several laser pulses. The Laser Peripherals RBLF-200 fiber fractured during initial but not repeat testing. One of three reusable Dornier DUR Laser Fibers failed during testing after the twentieth steam sterilization cycle. Five of five Boston Scientific Accuflex 200 failed at the SMA connector and did not couple well with the Lumenis Powersuite laser. The test hypothesis was not supported.
机译:该研究测试了重复蒸汽灭菌的假设将导致钬激光纤维失效的速率增加:在一系列市售的单一使用和可重复使用的小核心大小(200-272μm)钬:YAG激光器中纤维。测试单一使用和可重复使用的小芯尺寸的钬激光纤维。单用纤维包括Dornier Lighguide Super 200,Dornier Dur激光纤维单用,光学完整性Scopesafe 272,IQINC。 LLF200TG-D和LLF273TG-D,波士顿科学ACCUFLEX 200和ACCUFLEX 273和Lumenis Slimline EZ 200.可重复使用的纤维包括Dornier Dur激光光纤可重复使用,Lumenis Slimline 200,Sharplan 200,激光外围设备RBLF-200,IQINC。 LFT273NT,收敛OptiView SMH1020F。 Lumenis Versapulse 100瓦和PowerSuite 20瓦钬:使用YAG激光器。纤维在直径为1.5厘米的直径下弯曲至180度。将激光在1.5J,10Hz烧制30分钟或直至纤维骨折。使用制造商的规格将可重复使用的纤维灭菌共20个循环,并在每五个完成周期后重新测试。单独弯曲不弯曲纤维。三种Dornier Super 200单一使用纤维在几个激光脉冲中反复断裂。激光外围设备RBLF-200纤维在初始但不重复测试期间裂开。三种可重复使用的Dornier Dur激光纤维中的一种在第二十二蒸汽灭菌循环后测试期间失败。五个波士顿科学ACCUFLEX 200中的五个失败了SMA连接器,并没有与Lumenis PowerSuite激光相结合。不支持测试假设。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号