首页> 外文会议>International RF and Microwave Conference >Characteristics of Thyristor Surge Protection Devices Under Natural Lightning Surge Occurrences
【24h】

Characteristics of Thyristor Surge Protection Devices Under Natural Lightning Surge Occurrences

机译:自然雷电激增下晶闸管电涌保护装置的特点

获取原文

摘要

This paper presents results of residual voltages of thyristor surge protection devices (TSPD) observed experimentally at the real telecommunication subscriber lines connected to customer premises equipment (CPE). TSPD with DC firing voltage of 120Vdc is chosen based on local telecommunication utility's specification. Cumulative probability distribution of surge currents that discharged through TSPD and its energy dissipation are also demonstrated in this paper. The responses of TSPD against multiple-lightning-surges with up to six consecutive surges with the interval of several milliseconds are also shown here. The performance of TSPD against actual lightning surges is proven to be remarkable in which residual voltages measured are not more than 160V with the maximum discharged surge currents captured as high as 150A. Power utility's earth with the earth resistance values of approximately 50Ω is quite effective to divert surge currents away from the TSPD during lightning surge occurrences.
机译:本文介绍了晶闸管浪涌保护装置(TSPD)的残留电压的结果,在连接到客户楼宇设备(CPE)的真实电信用户线上实验观察。基于本地电信公用事业的规范,选择具有120VDC的直流烧制电压的TSPD。本文还证明了通过TSPD排出的血压电流的累积概率分布及其能量耗散。这里还显示了TSPD对多次闪电浪涌的响应,在此处显示多毫秒的间隔。证明,TSPD对实际雷电浪涌的性能是显着的,其中测量的残留电压不超过160V,最大放电浪涌电流捕获高达150A。电力公用事业的地球与接地电阻值约为50Ω,在避雷激增出现期间与TSPD转移远离TSPD的浪涌电流非常有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号