首页> 外文会议>SICE-ICASE International Joint Conference >Study on the Measurement Method of Leakage Flow-rate for Pneumatic Driving Apparatus
【24h】

Study on the Measurement Method of Leakage Flow-rate for Pneumatic Driving Apparatus

机译:气动驱动装置泄漏流量测量方法研究

获取原文

摘要

In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there was no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured by the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic apparatus. The effectiveness of the proposed method is proved by experimental results.
机译:在该研究中,提出了一种用于气动驱动装置的泄漏流量的测量方法。现有的泄漏流量率的测量方法需要拆卸测试组件。因此,在操作气动驱动装置时没有有效的方法测量泄漏流速。在该研究中,通过等温室中的压力变化来测量泄漏流速,其可以通过将钢丝绒填充到其中的等温条件。因此,可以仅从压力响应测量宽范围的流速,并且在操作气动装置期间可以测量泄漏流速。通过实验结果证明了该方法的有效性。