Study on the flow through erythrocyte membrane pores due to mechanical damage

机译:通过机械损伤引起的红细胞膜流量的研究

获取原文

摘要

The purpose of this study is to observe outflow of hemoglobin through a erythrocyte's membrane pore. Compressing erythrocytes, we observed the process of collapsing of erythrocyte's membrane with differential interference microscope. The compression was load using a piezo actuator. The particles of titanium dioxide were dispersed to measure the velocity of outflow. The velocity of outflow was approximately 10μm/s, and the diameter of a pore was estimated to be 0.9 μm/s. The pressure difference between membrane inside and outside was estimated to be about 1.26Pa.
机译:本研究的目的是通过红细胞膜孔观察血红蛋白的流出。压缩红细胞,我们观察到用差动干扰显微镜折叠红细胞膜的过程。使用压电致动器负载压缩。分散二氧化钛的颗粒以测量流出的速度。流出的速度约为10μm/ s,孔的直径估计为0.9μm/ s。据估计,膜内和外部的压力差异为约1.26Pa。