Stabilized Pd-alloy/AlN/Si Hydrogen Sensors

机译:稳定的PD-合金/ ALN / SI氢气传感器

获取原文

摘要

In order to extend the dynamic range of a hydrogen sensor with a metal-insulator-semiconductor (MIS) type structure, Pd-Cr and Pd-Ni alloy gated samples wertsstudied. The Pd-Cr gated sample shows quite stable and reproducible response, and could measure hydrogen concentrations from 100 to 50,000 ppm. While the Pd-Ni gated sample shows turn-on/off response drift, this drift is probably due to the presence of oxygen on the surface of the insulator and the formation of metal hydride. Furthermore, the effect of oxygen on the sensors response was investigated; oxygen may deplete protons from the metal/insulator interface and could reduce the sensor's response.
机译:为了将氢传感器的动态范围与金属 - 绝缘体 - 半导体(MIS)型结构延伸,PD-CR和PD-Ni合金门控样品致氟化。 PD-CR门控样品显示出相当稳定和可重复的反应,可以测量100至50,000ppm的氢浓度。虽然PD-NI门控样品显示导通/关闭响应漂移,但这种漂移可能是由于绝缘体表面上存在氧气以及金属氢化物的形成。此外,研究了氧对传感器反应的影响;氧气可以从金属/绝缘体界面耗尽质子,可以降低传感器的响应。