Progress in the UCTE-IPS/UPS electricity transmission system study causes the posing a question concerned the principles that could be used for coordination of so-called system protection schemes (SPS) for the impending interconnection. Multitude of ways to coordinate SPS is known but it is difficult to select some of them in the UCTE-IPS/UPS case. There is quantity of well known strategies for on-line dynamic security assessment (DSA) as well as large amount of approaches to SPS development in the power systems. At the same time, different practice of the use of SPS in the UCTE power system and the IPS/UPS can become an impediment to progress in unanimous strategy of SPS coordination. Peculiarities of deregulation in power systems produce supplementary obstacles. It is better to debate this topic before developing SPS coordinating structure for the UCTE-IPS/UPS. Two possible strategies for coordination of SPS in the UCTE-IPS/UPS interconnection are suggested. The structures of two modern Russian SPS complexes are proposed for consideration as probable prototypes for SPS complexes in the UCTE-IPS/UPS project. One of the approaches to power system state estimation that has to be fulfilled by SPS complexes and systems is briefly discussed. The suggestion that the general principles of DSA and the UCTE-IPS/UPS emergency control have to be tested at the European and Russian control centers is formulated. As possible places for such tests in Russia the Zeya and Bureya HPP's SPS complexes are shown.
机译:UCTE-IPS / UPS电力传输系统研究的进展导致构成问题涉及可用于协调所谓的系统保护方案(SPS)的原则,以便进行即将互连。耦合SPS的多种方式是已知的,但很难在UCTE-IPS / UPS案例中选择其中一些。在线动态安全评估(DSA)以及电力系统中SPS开发的大量方法存在众所周知的策略。与此同时,在UCTE电力系统中使用SPS的不同实践和IPS / UPS可以成为SPS协调的一致策略的障碍。电力系统放松管制的特点会产生补充障碍。在为UCTE-IPS / UPS开发SPS协调结构之前,最好讨论此主题。建议在UCTE-IPS / UPS互连中进行两个可能的用于协调SPS的可能策略。建议在UCTE-IPS / UPS项目中考虑两个现代俄罗斯SPS复合物的结构,以考虑为SPS复合物的可能原型。简要讨论了SPS复合体和系统必须满足的电力系统状态估计的方法之一。制定了DSA的一般原则和UCTE-IPS / UPS紧急控制的建议,制定了欧洲和俄罗斯对照中心的制定。作为俄罗斯在俄罗斯这种测试的可能位置,显示了Zeya和Bureya HPP的SPS复合物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号