An optical radiometric system based on a laser-illuminated integrating sphere, a pair of calibrated apertures and a calibrated silicon detector is described. The source comprises an integrating sphere with a direct-coupled 650 nm single-longitudinal-mode diode laser power stabilised to approx0.005 percent and wavelength stabilised to approx0.0006 nm. The effective areas of the apertures were measured to better than 0.005 percent using a macroscopic scanning probe technique. The responsivity of the 18 X 18 mm silicon detector was calibrated to better than 0.02 percent directly against a cryogenic radiometer. This system has applications in absolute radiometry and radiation thermometry. Overall, this system has uncertainties of < 0.04 percent. The system was used to replace the gold freezing point as a reference radiance source for radiation thermometry. Although its performance as a radiance reference is excellent, preliminary results in its application to radiation thermometry are presently limited by coherent interreflection within the pyrometer optics.
机译:描述了一种基于激光照射积分球的光学辐射系统,描述了一对校准的孔和校准的硅检测器。源包括具有直接耦合的650nm单纵型二极管激光功率的集成球,稳定为大约0.005%,波长稳定为大约0.0006nm。使用宏观扫描探针技术测量孔的有效区域以优于0.005%。将18×18mm硅探测器的响应性校准以优于低温辐射计的0.02%。该系统具有绝对辐射和辐射温度的应用。总的来说,该系统的不确定性<0.04%。该系统用于将金冰点替换为辐射温度的参考辐射源。尽管其作为辐射参考的优异性能优异,但其在其对辐射温度的应用中的初步结果目前受到高温计光学内部的相干释钝的限制。