首页> 外文会议>Conference on laser-generated and other laboratory x-ray and EUV sources, optics, and applications >Quasi-monochromatic polycapillary imaging utilizing a computed radiography system
【24h】

Quasi-monochromatic polycapillary imaging utilizing a computed radiography system

机译:利用计算的射线照相系统的准单色多百分子成像

获取原文

摘要

A fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a copper-target x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the anode electrode is connected to the ground. In this experiment, the tube voltage was regulated from 12 to 22 kV, and the tube current was regulated within 3.0 mA by the filament temperature. The exposure time was controlled in order to obtain optimum x-ray intensity, and the maximum focal spot dimensions were approximately 2.0 * 1.5 mm. The polycapillary plate was J5022-16 (Hamamatsu Photonics Inc.), and the plate thickness was 1.0 mm. The outer, effective, and hole diameters were 33 mm, 27 mm, and 10 μm, respectively. Quasi-monochromatic x-rays were produced using a 10 μm-thick copper filter with a tube voltage of 17 kV, and these rays were formed into parallel beams by the polycapillary. The radiogram was taken using a computed radiography system utilizing imaging plates. In the measurement of image resolution, the resolution hadly varied according to increases in the distance between the chart and imaging plate using a polycapillary. We could observe a 50 μm tungsten wire clearly, and fine blood vessels of approximately 100 μm were visible in angiography.
机译:描述了使用多百分子板和铜靶X射线管的准单色平行放射线照相的基本研究。 X射线发生器包括负高压电源,长丝(热阴极)电源和X射线管。负高电压施加到阴极电极,并且阳极连接到地面。在该实验中,管电压从12至22kV调节,并且管电流通过细丝温度调节在3.0 mA内。控制曝光时间以获得最佳的X射线强度,最大焦点尺寸约为2.0 * 1.5mm。多毛细管是J5022-16(Hamamatsu Photonics Inc.),板厚为1.0mm。外部,有效和孔径分别为33mm,27mm和10μm。使用具有17kV的管电压的10μm厚的铜过滤器生产准单色X射线,并且这些射线由多百分点形成并联梁。使用使用成像板的计算放射线照相系统进行射线图。在图像分辨率的测量中,根据使用多递比的图表和成像板之间的距离的增加而变化。我们可以清楚地观察50μm钨丝,在血管造影中可见大约100μm的细血管。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号