A multi-sample test system has been created with advanced control techniques, which allow the user to individually monitor the fracture of nitinol single apex samples cut from an endovascular device. The system can reliably detect a reduction in load of less than one gram at test frequency indicating impending failure on each station and increases the rate of data acquisition on the specified station where the load falloff precursors are detected. The software used allows the operator to record peak-valley load data as needed for long term fatigue but also has the ability to capture a user defined number of cycles of that load cell only when a load drop-off occurs without the burden of recording the data from all of the load cells in the test. Only the test site of interest is magnified and detailed. Following a fracture, the system allows the user to decide if the test should continue, pause in order to remove the damaged specimen, or terminate, without damaging any of the other samples.
机译:已经采用高级控制技术创建了多样品测试系统,其允许用户单独监测从血管内装置切割的镍钛诺单顶点样本的骨折。该系统可以可靠地检测在测试频率下,在每个站上迁移发生故障的测试频率可靠地检测负载的减小,并增加检测到负载衰减前体的指定站上的数据采集速率。所用的软件允许操作员根据长期疲劳的需要记录峰值谷负载数据,但是当时才能在没有记录的负担的情况下发生负载下降时捕获该负载单元的用户定义数量的循环。测试中所有称重传感器的数据。只有感兴趣的测试站点被放大和详细。在骨折之后,系统允许用户确定测试是否应继续,暂停,以便去除损坏的样本或终止,而不会损坏任何其他样本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号