A new 4.5K cold box at Jefferson Lab (JLab) Cryogenic Test Facility (CTF) was recently installed and commissioned to upgrade the existing 4.5 K refrigeration system and work in parallel with the existing 4.5 K cold box. This new 4.5 K cold box is equipped with two turbo-expanders and, at its maximum capacity condition, it is expected to support at least 6.6 g/s of helium liquefaction or 650 W of refrigeration at 4.5 K. It can also handle up to 10 g/s 30 K return flow for 2 K refrigeration recovery that supports cryo-module and superconducting cavity testing. Performances of the cold box at its maximum capacity conditions as well as several other operating modes were tested for acceptance. We will briefly review the new 4.5 K cold box design features and discuss the commissioning and performance testing results.
机译:杰斐逊实验室(JLAB)低温测试设施(CTF)的一个新的4.5k冷箱最近安装并委托升级现有的4.5 k制冷系统,并与现有的4.5 k冷箱平行工作。这个新的4.5 k冷箱配有两个涡轮扩展器,并且在其最大容量条件下,预计将支撑至少6.6克/秒的氦液化或650瓦的冷藏4.5 K.它也可以处理10 G / s 30 k返回流量用于2 k制冷恢复,支持低温模块和超导腔测试。测试了冷箱在最大容量条件下的表演以及其他几种操作模式的接受。我们将简要介绍新的4.5 K冷箱设计功能,并讨论调试和性能测试结果。