首页> 外文会议>Audio Engineering Society Convention >HRIR database with measured actual source direction data
【24h】

HRIR database with measured actual source direction data

机译:HRIR数据库,具有测量的实际源方向数据

获取原文

摘要

A database is presented consisting of head-related impulse responses (HRIR) of 21 subjects measured in anechoic chamber with simultaneous measurement of head position and orientation. The HRIR data for sound sources at 1.35 m and 68 cm in 240 directions with elevations between ±45° and full azimuth range were measured using blocked ear canal method. The frequency region of the measured responses ranges from 100 Hz up to 20 kHz for a flat response (+0.1 dB / -0.5 dB). This data is accompanied with the measured azimuth and elevation of the source respect to the position and orientation of the subject's head obtained with a tracking system based on infrared cameras. The HRIR data is accessible from the Internet.
机译:提出了一种数据库,其由在Alecoic室中测量的21个受试者的头相关脉冲响应(HRIR)组成,其具有同时测量头部位置和方向。使用堵塞的耳道法测量,在240方向上为1.35米和68厘米的声源的HRIR数据在±45°和全方位角范围之间测量。测量响应的频率区域为扁平响应(+0.1dB / -0.5dB)的100Hz高达20kHz。该数据伴随着测量的方位角和源的升高,以及基于红外摄像机的跟踪系统获得的受试者头部的位置和取向。 HRIR数据可从Internet访问。