Cavity ring-down spectroscopy (CRDS) can provide high sensitivity, high precision, and absolute calibration in a wide range of environments. We report on a compact cavity ring-down spectrometer that can measure atmospheric toxic industrial compounds such as hydrides and hydrazines. The ring-down spectrometer is fully contained in two 5 1/4" tall, 19" wide rack mount enclosures and utilizes a robust, near-infrared, fiber-coupled tunable diode laser. The instrument has a baseline sensitivity of 8 * 10~(-11) cm~(-1)/Hz~(1/2). We will present the results of this study, which demonstrates the capability to detect toxic gases such as arsine, silane, and hydrazine (simulated using ammonia) in air at parts per billion (ppb) concentrations in less than 1 minute. We will also present results on CRDS instrument performance, including zero drift, precision, absolute accuracy, and linearity over a wide range of environmental operating conditions.
机译:腔斜频谱光谱(CRD)可以在各种环境中提供高灵敏度,高精度和绝对校准。我们报告了一个紧凑的腔响声光谱仪,可以测量富含氢化物和肼的大气毒性工业化合物。折断光谱仪完全包含在两个5 1/4“高19”宽机架安装外壳中,并利用稳健,近红外光纤可调二极管激光器。该仪器具有8 * 10〜(-11)cm〜(-1)/ hz〜(1/2)的基线敏感性。我们将介绍本研究的结果,该结果表明,在少数1分钟内,在每十亿(PPB)浓度下,在空气中检测有毒气体如砷,硅烷和肼(模拟)的能力。我们还将在CRD仪器性能上提出结果,包括零漂移,精度,绝对精度,以及在各种环境操作条件范围内的线性。