There are two aspects of the joints that we are relating to in this article. The first one, which can be assign to the bad workmanship, is the experimentally supported evaluation of the influence of the large proportion of the overgrained sand particles on the mechanical properties of the traditional brick masonry. The tests of the masonry which were carried out through compressive test of masonry specimens of the size of the wallette as well as through bond tests showed the significant influence of sand gradation both on the compressive strength of the masonry and on the bond strength of the brick-mortar junction. The second aspect, which according to some codes can be attributed either to the bad workmanship or to the inappropriate construction technique, is execution of the head joints in contemporary block masonry and its possible impact on the overall resistance of the masonry due to the earthquake load. Although the problems related to the execution of the head joints and its influence on the shear strength of the masonry is partly incorporated in the new EC 6 (EUROCODE 6, 1997), there is still lack of knowledge of the overall resistance of masonry under the earthquake loading. According to the EC 8 (EUROCODE 8, 1994) except in zones of low seismicity (a_g≤0.05 g.) perpend (head) joints should be fully filled with mortar. This clause, as well as some recent research results on that topic, can limit the applicability of many modern types of newly developed clay blocks in earthquake prone areas.
机译:我们在本文中有两个方面。可以分配到糟糕的工艺的第一个是通过实验支持的大部分覆盖砂颗粒对传统砖砌体的机械性能的影响的评估。通过吊墙尺寸的砌体标本的压缩试验进行的砌体测试以及通过粘合试验表现出砂坯的显着影响,这两者都对砌体的抗压强度和砖的粘合强度-mortar结。根据一些代码的第二方面可以归因于糟糕的工艺或不适当的施工技术,是当代块砌体中的头部接头及其对由于地震载荷导致砌体的整体电阻的影响。尽管与执行头关节的执行问题及其对砌体剪切力量的影响部分是新的EC 6(Eurocode 6,1997),但仍然缺乏对砖石下的总体抵抗的了解地震装载。根据EC 8(EUROCODE 8,1994),除了低地震区的区域(A_G≤0.05克),持续(头)关节应完全充满砂浆。该条款以及最近的一些研究结果对该话题来说,可以限制许多现代类型的新开发的粘土块在地震俯卧面积中的适用性。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号