We report on the characterization of bolometers fabricated at the Jet Propulsion Laboratory for the High Frequency Instrument (HFI) of the joint ESA/NASA Herschel/Planck mission to be launched in 2007. The HFI is a multicolor focal plane which consists of 48 bolometers operated at 100mK. Each bolometer is mounted to a feedhorn-filter assembly which defines one of six frequency bands centered between 100-857GHz. Four detectors in each of six bands are coupled to both linear polarizations and thus measure the total intensity. In addition, eight detectors in each of 3 bands (143, 217, and 353GHz) couple only to a single linear polarization and thus provide measurements of the Stokes parameters, Q and U, as well the total intensity. The detectors are required to achieve a Noise Equivalent Power (NEP) at or below the background limit ~ 10~(-17)W/(Hz)~(1/2) for the telescope and time constants of a few ms, short enough to resolve point sources as the 5 to 9 arc-minute beams move across the sky in great circles at 1 rpm. The bolometers are tested at l00mK in a commercial dilution refrigerator with a custom built thermal control system to regulate the heat sink with precision < 100nK/(Hz)~(1/2). The l00mK tests include dark electrical characterization of the load curves, optical and electrical measurement of the thermal time constants and measurement of the noise spectral density from 0.01 to 10Hz for up to 24 bolometers simultaneously.
机译:我们在2007年推出的高频仪表(HFI)中展示了在2007年联合ESA / NASA HERSCHER / Planck任务的高频仪器(HFI)所制作的钻孔计的特征.HFI是一个由48个钻孔计组成的多色焦平面在100mk。每个钻镜安装到进料堆过滤器组件,该滤波器组件定义六个频带中的一个,以100-857GHz为中心。六个频带中的每一个中的四个探测器耦合到线性偏振,从而测量总强度。另外,3个频带(143,217和353GHz)中的每一个的八个探测器仅耦合到单线性极化,从而为斯托克斯参数,Q和U的测量提供了总强度。探测器需要在望远镜和时间常数的背景下限〜10〜(-17)w /(hz)〜(1/2)处或下方的噪声等效功率(NEP)。要将点源解析为5到9个弧形横梁,在1 rpm的圆圈中移动天空。钻孔器在L00MK中在商用稀释冰箱中测试,具有定制的热控制系统,以通过精密<100nk /(Hz)〜(1/2)调节散热器。 L00MK测试包括热时间常数的负载曲线,光学和电测量的暗电气表征,并同时测量0.01至10Hz的噪声光谱密度最多24孔计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号