We have designed a thermal conductivity measuring apparatus using the Cyclic Heat, the Transient Hot Wire, and the Hot Disk methods. Using the apparatus, the thermal conductivities of Polyurethane foams were measured in the temperature range from -170°C to 25°C. Comparison of measured values using the Transient Hot-Wire method with the Cyclic Heat and the Hot Disk methods indicated good agreement. It was confirmed that the results of measurement using different methods agree with each other under the conditions of using the same specimen and conducting measurements under the same environment. However, measured values using the Cyclic Heat method at temperatures near 0°C were larger than those obtained by other methods. It was because that, when a heat wave with the amplitude about 4°C was conducting through the specimen, the moisture in the specimen changed phases (between ice and water) periodically. Measured values using the Hot Disk method in the temperature range from -170°C to -120°C were smaller than the others.
机译:我们设计了使用循环热量,瞬态热线和热盘方法的导热测量装置。使用该装置,在-170℃至25℃的温度范围内测量聚氨酯泡沫的热导率。使用循环热量和热盘方法使用瞬态热线方法的测量值的比较表明良好的一致性。证实,使用不同方法的测量结果在使用相同标本和在相同环境下进行测量的条件下彼此一致。然而,在0℃接近0℃的温度下使用循环热法的测量值大于通过其他方法获得的循环热法。这是因为,当具有约4℃的幅度的热波通过样品进行,所以样本中的水分定期改变阶段(冰和水之间)。使用热磁盘法在-170°C至-120°C的温度范围内的测量值小于其他温度范围。