The faulty performance of six diodes three phase rectifier is studied under one and two simultaneous open-diodes conditions. This rectifier is feeding a resistive load. The rectifier three phases currents zero harmonic components and their maximum and minimum values are used as diagnostic indices. A knowledge algorithm is based to get information on which diode is in open-switch fault condition. This algorithm testing shows that the system could not only detect the open-switch fault, but also identify the faulty switches. Presented simulation results confirm the effectiveness of the proposed methodology.
机译:在一个和两个同时开放二极管条件下研究了六个二极管三相整流器的故障性能。该整流器馈送电阻负载。整流器三相电流零谐波分量,其最大值和最小值用作诊断索引。知识算法基于获取哪些二极管处于开关故障状态的信息。该算法测试表明,该系统不仅可以检测开关故障,还可以识别故障交换机。呈现的仿真结果证实了提出的方法的有效性。