首页>
外文OA文献
>Conception and implementation of single and simultaneous two diodes open faults automatic detection and localization algorithm in six diodes three phase rectifier bridge
【2h】
Conception and implementation of single and simultaneous two diodes open faults automatic detection and localization algorithm in six diodes three phase rectifier bridge
The faulty performance of six diodes three phase rectifier is studied under one and two simultaneous open-diodes conditions. This rectifier is feeding a resistive load. The rectifier three phases currents zero harmonic components and their maximum and minimum values are used as diagnostic indices. A knowledge algorithm is based to get information on which IGBT is in open-switch fault condition. This algorithm testing shows that the system could not only detect the open-switch fault, but also identify the faulty switches. Presented simulation results confirm the effectiveness of the proposed methodology
展开▼