Seismic performance of coupling beams designed according to non-seismic provisions is examined. Coupling beam specimens in 1/4 scale were tested under cycles of end shear. Characteristics of the specimens include high main reinforcement ratio, about 3-4%, and large spacing of links with 90-degree hooks. Based on the test data, 140mm is recommended to be the optimal spacing of links. Furthermore, coupling beams must not be heavily reinforced. Since this would lead to substantial reduction in the displacement ductility and ultimate drift ratio. Finally, an empirical relationship is proposed to estimate the ultimate drift ratio of non-ductile coupling beams.
机译:检查根据非地震尺寸设计的耦合光束的地震性能。在末端剪切的循环下测试1/4刻度中的耦合束标本。标本的特性包括高的主增强率,约3-4%,以及具有90度钩的链接的大间距。基于测试数据,建议140mm是链接的最佳间距。此外,耦合梁不得重大加固。由于这将导致位移延性和最终漂移比率大幅度降低。最后,提出了一种经验关系来估计非延展耦合光束的最终漂移比。