This work presents a method allowing the calculation of enthalpy of a refrigerant/oil mixture. To generalise this method, the considered refrigerant is also a mixture with a temperature glide (R407C). The suggested method requires the knowledge of the mixture liquid-vapour equilibrium properties (solubility curves) and the oil thermodynamic properties. In a first application of the model, the ln(P)-h-X' diagram for the refrigerant/oil mixture is plotted. Then, the ratios of the enthalpy changes through an evaporator, with and without taking into account the effect of oil are compared for several conditions (varying superheat, compression ratio). The results for the studied refrigerant/oil pair show that the calculated enthalpy change through the evaporator depends much on taking into account the effect of oil, since the relative decrease may reach 34% for a low superheat and a high oil mass-fraction. Lastly, the prediction of the quantity of the refrigerant dissolved in oil (and consequently that remains non-evaporated) at the outlet of an evaporator is performed for various superheats.
机译:该工作提出了一种方法,允许制冷剂/油混合物的焓计算。为了概括这种方法,所考虑的制冷剂也是一种与温度滑动(R407c)的混合物。建议的方法需要了解混合物液 - 蒸汽平衡性质(溶解度曲线)和油热力学性质。在模型的第一次应用中,绘制制冷剂/油混合物的LN(P)-H-X'图。然后,将焓变化通过蒸发器的比率,并且在没有考虑到油的效果,以进行几种条件(不同的过热,压缩比)。所研究的制冷剂/油对的结果表明,通过蒸发器的计算焓变化在考虑到油的效果,因为相对降低可以达到低过热和高油质量级分的34%。最后,对蒸发器的出口进行溶解在油中的制冷剂的量(并且因此在蒸发器的出口中预测,用于各种过热。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号