摘要

In Croatian Podravina relatively large quantities of natural gas was discovered. From various fields (Molve, Kalinovec, Stari Gradec) natural gas is pipelined to Gas Treatment Plant (GTP) Molve. Here, at GTP Molve Ⅲ, technological procedures for purification of natural gas and its distribution are performed. With yearly natural gas production of 3,5 10~9 m~3 GTP Molve Ⅲ is major Croatian energy resource. Its safety and environment impact is matter of concern. Continuous acoustic emission leak monitoring system for Gas Treatment Plant (GTP) Molve as an improvement in technological and environment safety is considered. Application of a leak monitoring system under industrial conditions is a problem setting specific demands. In the paper attention is paid to some aspects of acoustic emission system implementation and the acoustic background noise definition problem. Acoustic noise measurements at a GTP Molve Ⅲ were performed and some results considering background noise are presented. In the paper acoustic noise measurements performed at a GTP Molve Ⅲ were presented. Across the GTP Molve Ⅲ acoustical background have different spectral and amplitude characteristic. In the input area, measurements presented at a first group of measuring points included the impact of sand moved by gas fluid. Sand hits should be distinguished from acoustic emission caused by growing cracks. Motors noise and turbulence around valves are probably the main source of background noise on second group of measuring The conclusion is that background noise across the plant is highly different. Patterns found in one part of plant could not be applied on others measuring points. Background noise and its characterization are one of main problems solved before reliable operation of acoustic monitoring system could be applied. It is found that at GTP Molve Ⅲ acoustic background is complicated, consisting of different sources at different part of a plant.
机译:在克罗地亚罗拉夫纳,发现了相对大量的天然气。从各个领域(Molve,Kalinovec,Stari Gradec)天然气流水处理植物(GTP)莫尔。这里,在GTPMolveⅢ,进行纯化天然气的技术程序及其分布。每年天然天然气生产3,510〜9米〜3 GTPⅢ,是主要的克罗地亚能源资源。其安全和环境影响是关注问题。考虑了用于天然气处理厂(GTP)莫尔的连续声发射泄漏监测系统,作为技术和环境安全的改善。泄漏监测系统在工业条件下的应用是一个具体要求的问题。在文章中,注意到声发射系统实现和声学背景噪声定义问题的某些方面。对GTPMolveⅢ进行声学噪声测量Ⅲ,呈现了考虑背景噪声的一些结果。在纸张上,介绍了在GTPMolveⅢ进行的声学噪声测量。在GTP莫尔维Ⅲ型声学背景上具有不同的光谱和幅度特性。在输入区域中,在第一组测量点处呈现的测量包括气体砂的抗冲击。应与由生长裂缝引起的声发射来区分沙击。电动机噪音和阀门周围的湍流可能是第二组测量的背景噪音的主要来源,结论是整个植物的背景噪音高度不同。在植物的一部分中发现的模式无法应用于其他测量点。背景噪声及其表征是可以应用声学监控系统可靠运行之前解决的主要问题之一。结果发现,在GTP莫尔维Ⅲ,声学背景是复杂的,由植物不同部分的不同来源组成。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号