首页> 外文会议>2002 Engineering Technology Conference on Energy, Feb 4-5, 2002, Houston, Texas >BACKGROUND NOISE DEFINITION FOR ACOUSTIC EMISSION LEAK MONITORING SYSTEM AT GTP MOLVE
【24h】

BACKGROUND NOISE DEFINITION FOR ACOUSTIC EMISSION LEAK MONITORING SYSTEM AT GTP MOLVE

机译:GTP熔池声发射泄漏监测系统的背景噪声定义

获取原文
获取原文并翻译 | 示例

摘要

In Croatian Podravina relatively large quantities of natural gas was discovered. From various fields (Molve, Kalinovec, Stari Gradec) natural gas is pipelined to Gas Treatment Plant (GTP) Molve. Here, at GTP Molve Ⅲ, technological procedures for purification of natural gas and its distribution are performed. With yearly natural gas production of 3,5 10~9 m~3 GTP Molve Ⅲ is major Croatian energy resource. Its safety and environment impact is matter of concern. Continuous acoustic emission leak monitoring system for Gas Treatment Plant (GTP) Molve as an improvement in technological and environment safety is considered. Application of a leak monitoring system under industrial conditions is a problem setting specific demands. In the paper attention is paid to some aspects of acoustic emission system implementation and the acoustic background noise definition problem. Acoustic noise measurements at a GTP Molve Ⅲ were performed and some results considering background noise are presented. In the paper acoustic noise measurements performed at a GTP Molve Ⅲ were presented. Across the GTP Molve Ⅲ acoustical background have different spectral and amplitude characteristic. In the input area, measurements presented at a first group of measuring points included the impact of sand moved by gas fluid. Sand hits should be distinguished from acoustic emission caused by growing cracks. Motors noise and turbulence around valves are probably the main source of background noise on second group of measuring The conclusion is that background noise across the plant is highly different. Patterns found in one part of plant could not be applied on others measuring points. Background noise and its characterization are one of main problems solved before reliable operation of acoustic monitoring system could be applied. It is found that at GTP Molve Ⅲ acoustic background is complicated, consisting of different sources at different part of a plant.
机译:在克罗地亚的波德拉维纳,发现了相对大量的天然气。来自各个领域(Molve,Kalinovec,Stari Gradec)的天然气通过管道输送到气体处理厂(GTP)Molve。在这里,在GTP MolveⅢ,执行了天然气纯化及其分布的技术程序。克罗地亚每年的天然气产量为3,5 10〜9 m〜3 GTP MolveⅢ。它对安全和环境的影响值得关注。考虑到用于气体处理厂(GTP)的连续声发射泄漏监测系统,以改善技术和环境安全性。在工业条件下泄漏监测系统的应用是设定特定要求的问题。在本文中,注意力集中在声学发射系统实现的某些方面以及声学背景噪声的定义问题上。在GTP MolveⅢ处进行了声学噪声测量,并给出了一些考虑背景噪声的结果。在论文中,介绍了在GTP MolveⅢ处进行的噪声测量。在整个GTP中,MolveⅢ的声学背景具有不同的频谱和振幅特性。在输入区域中,在第一组测量点处显示的测量结果包括由气体流体移动的沙子的冲击。沙击应与裂纹扩展引起的声发射区分开。阀门周围的马达噪声和湍流可能是第二组测量中背景噪声的主要来源。结论是整个工厂的背景噪声差异很大。在植物某一部位发现的模式无法应用于其他测量点。背景噪声及其表征是在应用声监控系统可靠运行之前要解决的主要问题之一。研究发现,在GTP上,MolveⅢ的声学背景很复杂,由植物不同部分的不同来源组成。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号