This is the second paper exploring the effects of the degradation of different components on Combined Cycle Gas Turbine (CCGT) plant performance. This paper investigates the effects of degraded steam path components of steam turbine (bottoming) cycle have on CCGT power plant performance. Areas looked at were, steam turbine fouling, steam turbine erosion, heat recovery steam generator degradation (scaling and/or ashes deposition), and condenser degradation. The effect of gas turbine back-pressure on plant performance due to HRSG degradation is also discussed. A general simulation Fortran code was developed for the purpose of this study. This program can calculate the CCGT plant design point performance, off-design plant performance, and plant deterioration performance. The results obtained are presented in a graphical form and discussed.
机译:这是探讨不同部件劣化对组合循环燃气轮机(CCGT)植物性能的第二篇论文。本文研究了汽轮机(底层)循环降解蒸汽路径部件对CCGT发电厂性能的影响。看着领域是,汽轮机污垢,汽轮机腐蚀,热回收蒸汽发生器降解(缩放和/或沉积),和冷凝器降解。还讨论了燃气轮机背压对由于HRSG降解引起的植物性能的影响。对于本研究的目的,开发了一般仿真代码。该计划可以计算CCGT工厂设计点性能,非设计植物性能和植物恶化性能。获得的结果以图形形式呈现并讨论。

著录项