Results of the environmental update of GT-750-6 ("Nevsky Zavod", 6 MW), KWU VR-438 ("Siemens", 10 MW), MS-3002 ("General Electric", 10 MW) gas-turbine unit combustors were examined. On the basis of some specific features of design and operating process in the combustors, original engineering approaches of their update using a technique of localized air blow into the fire space extreme temperature zones were developed. The technique was demonstrated to be effective for a variety of combustors. Using the technique, one needs no considerable changes of the combustor design. The fuel system and gas turbine plant automatic control and governing systems remain virtually intact.
机译:GT-750-6环境更新结果(“Nevsky Zavod”,6 MW),KWU VR-438(“西门子”,10 MW),MS-3002(“通用电气”,10 MW)燃气轮机单元检查了燃烧器。在燃烧器中的设计和操作过程的一些特定特征的基础上,开发了使用本地化空气吹入防火空间极端温度区域的原始工程方法。该技术被证明是对各种燃烧器有效。使用该技术,一种不​​需要燃烧器设计的相当大的变化。燃料系统和燃气轮机厂自动控制和控制系统几乎完整。