This paper describes the design of a 300MW HTGR-GT power plant which was completed in the framework of the HTGR-GT feasibility study project. The project is assigned to JAERI by the Science and Technology Agency of Japan. The inlet and outlet gas temperatures in the reactor are 550°C and 900°C, respectively. Helium gas pressure is 6MPa. The turbine system is a recuperative intercooled direct cycle one. Designs of helium turbine, LP and HP compressors and generator are presented, whose adiabatic efficiencies are 93.09, 89.92 and 90.25%, respectively. A horizontal single-shaft configuration was adopted whose rotor dynamics is given.
机译:本文介绍了在HTGR-GT可行性研究项目框架内完成的300MW HTGR-GT电厂的设计。该项目由日本科技机构分配给Jaeri。反应器中的入口和出口气体温度分别为550℃和900℃。氦气压力为6MPa。涡轮机系统是一种恢复的间接直接循环。提出了氦涡轮机,LP和HP压缩机和发电机的设计,其绝热效率分别为93.09,89.92和90.25%。采用水平单轴配置,其转子动力学是给出的。