首页> 外文会议>Conference on Percision Electromagnetic Measurements >Calibration of 10HM based on a QHR standard using a commercial DCC bridge
【24h】

Calibration of 10HM based on a QHR standard using a commercial DCC bridge

机译:基于QHR标准使用商业DCC桥校准10HM

获取原文

摘要

A calibration technique of 1 Ω based on a QHR standard(i=4 step) using a commercial DCC bridge have been described. Sample characterizations and bridge ratios have been measured using the DCC bridge without a CCC bridge and total combined uncertainty is estimated as about O.1×1O{sup}(-6) level.
机译:已经描述了使用商业DCC桥的QHR标准(I = 4步)的基于QHR标准(I = 4步)的校准技术。使用没有CCC桥的DCC桥来测量样本特征和桥梁比,并且估计总组合的不确定性约为O.1×1o {sup}( - 6)水平。