When several cool/heat tubes are buried under ground with narrow pitch, the heat exchange ability dropped by influence of adjacent tubes. Though each tube needs sufficient distance for buried, tubes are buried with narrow space under ground on account of the restriction of the site and excavation costs. Therefore, this study aims at developing a obvious design technique for the system. In this paper, the efficiency of Multi- cool/heat tube was evaluated from the measurement result. Finally, numerical analysis was performed in order to investigate the performance of this system for long-term operation.
机译:当在接地下用窄间距埋地时,通过相邻管的影响下降的热交换能力。虽然每个管需要足够的距离埋入,但是由于场地的限制和挖掘成本而下,管道埋在地面下的狭窄空间。因此,本研究旨在为系统开发明显的设计技术。本文从测量结果评估了多冷/热管的效率。最后,进行数值分析,以研究该系统的长期操作的性能。