Intake model test for circulating water pumps: comparison of model tests with flow analysis

机译:循环水泵的进气模型试验:流动分析模型试验比较

获取原文

摘要

An intake model test and a flow analysis were performed on the pump suction sump of a certain power station (250 MW× 2, PFBC). The test was carried out to assist in the design of the most suitable suction sump, where two circulating water pumpseach with a bellmouth diameter of 2,700 mm and a capacity of 35,000 m{sup}3/hr are installed. Air entraining vortices were observed at the medium velocity under the similarity condition. These vortices disappeared due to an improvement in the sumpconfiguration inserting baffle plate by trial and error using flow analysis. The flow analysis simulated effectively the results of the model test.
机译:在一定发电站(250mW×2,PFBC)的泵抽吸贮槽上进行进气模型测试和流量分析。进行测试以帮助设计最合适的吸入贮槽,其中安装了贝尔茅斯直径为2,700毫米的循环水泵和35,000 m {sup} 3 / hr的容量。在相似性条件下在培养基中观察空气夹带涡旋。由于使用流量分析,通过试验和误差插入挡板的改善,这些涡流消失了。流程分析有效地模拟了模型测试的结果。