首页> 外文会议>SAE Aerospace Atlantic Conference and Exposition >Evaluation of a basic Doppler Global Velocimetry system
【24h】

Evaluation of a basic Doppler Global Velocimetry system

机译:基本多普勒全局测速系统评估

获取原文

摘要

A basic one-component Doppler Global Velocimetry (DGV) system has been developed at Wichita State University. This system was evaluated on a round axisymmetric jet. The results are compared with measurements made using traditional Constant Temperature Anemometry (CTA) and Preston tube measurements at 3.2, 9.6 and 16.0 jet exit diameters downstream and along the jet centerline. The DGV results show similar trends to these measurements. Software corrections for camera misalignment, optical distortions, and laser frequency variations were necessary to assure data quality. Results indicate good agreement between the DGV and CTA measurements exists.
机译:在威奇托州立大学开发了基本的单组分多普勒全局测速仪(DGV)系统。该系统在圆轴对称喷射器上进行评估。将结果与使用在3.2,9.6和16.0喷射出口直径下和沿喷射中心线的3.2,9.6和16.0喷射出口直径进行的传统恒温性低温(CTA)和普雷斯顿管测量进行比较。 DGV结果显示出这些测量的类似趋势。对相机错位,光学扭曲和激光频率变化的软件校正是为了确保数据质量所必需的。结果表明DGV和CTA测量之间的良好一致性。