Ontario Power Generation (OPG) has developed and implemented a systematic managed process for steam generators at all of its facilities. One of the key requirements of this managed process is to have in place long range Steam Generator Life Cycle Management (SG LCM) plans for each of its reactor units. The primary goal of these plans is to maximize the value of the nuclear facility through safe and reliable steam generator operation over the expected life of the units. These SG LCM plans integrate and schedule all steam generator actions such as inspection, operation, maintenance, repairs, modifications, assessments, performance monitoring, research and development, and feedback.This paper provides an overview of how structural and leak-rate testing, being conducted by OPG, is being used to support fitness-for-service assessments for fretting degradation in the U-bend region of the recirculating steam generators at the Darlington Nuclear Generating Station.
机译:安大略省发电(OPG)已开发并实施了所有设施的蒸汽发生器的系统管理过程。该管理过程的一个关键要求是为每个反应堆单元的长期蒸汽发生器生命周期管理(SG LCM)计划提供。这些计划的主要目标是通过安全可靠的蒸汽发生器操作在单位的预期寿命上通过安全可靠的蒸汽发生器来最大限度地提高核设施的价值。这些SG LCM计划集成和安排所有蒸汽发生器动作,如检查,操作,维护,维修,修改,评估,性能监控,研发以及反馈。本文概述了结构和漏率测试的概述由OPG进行,用于支持在达林顿核发电站的再循环蒸汽发生器的U形弯区中的释放劣化的适应性评估。