Coatings are applied to structures and components in nuclear power plants, both inside and outside containment. The coatings applied to safety-related structures, systems, and components inside containment are classified a Service Level Ⅰ Coating, and coating systems outside of primary containment, but which in the event of a failure could adversely affect the orderly and safe shutdown of the plant are classified a Service Level Ⅲ coating. Weaknesses have been found in existing programs in regards to application of protective coatings for Service Level 1. This weakness is evident as blistering, cracking or peeling. For the extended period of operation, the licensee must demonstrate to in-place coating is qualified except for coatings shown on an Unqualified Coatings List; that the amount of unqualified coatings will not clog sump screens, strainers, or other safety-related equipment; and that coating assessment is being made at each refueling outage This paper will discuss the elements of a good coating program for the period of extended operation to ensure that existing coating systems are qualified; and that unqualified and degraded coatings will not clog strainers, screens or other safety-related equipment.
机译:涂层应用于内外核电站的结构和部件。应用于安全相关结构,系统和内部容器中的组件的涂层被分类为Ⅰ型Ⅰ型涂层,以及在主要遏制外的涂层系统,但在发生故障时可能对植物有序和安全关闭的事件产生不利影响分类为服务水平Ⅲ涂层。在现有的方案中发现了缺点,以适用于服务级别的保护涂层1.这种弱点是由于起泡,开裂或剥离的弱点。对于延长的操作期,许可人必须证明就地涂料是合格的,但除了不合格的涂料列表上显示的涂层外;不合格的涂层的数量不会堵塞油底壳筛,过滤器或其他与安全相关的设备;并且正在每次加油中断进行涂层评估本文将讨论延长运行期间良好涂层计划的要素,以确保现有涂层系统合格;并且不合格和降解的涂层不会堵塞过滤器,屏幕或其他与安全相关的设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号