In cell/tissue cryopreservation, cryoprotective agents (CPAs) should be added before freezing and removed after thawing. Nowadays people mainly apply centrifugation for CPA removal, which may cause many problems. Meanwhile, a simple and cheap method for real-time monitoring of the residual CPA concentration during processing remains an unfilled need. In this work, a "dilution-filtration" system with hollow fiber dialyzer was implemented and approved to remove dimethyl sulfoxide (Me_2SO) effectively. Compared to other methods (centrifugation and microfluidic approach), this one holds advantages of low time and labor consumption, low osmotic injury to the cells, high effectiveness, ease to control the final suspension volume and low risk of contamination. The "dilution-filtration" system can also be easily modified for CPA addition and cell suspension volume control (concentration or dilution of cell suspension). Meanwhile, a method of electrical conductivity (EC) measurement was applied to monitor the residual CPA concentration. The results showed EC measurements of waste solution can convey the CPA concentrations in cell suspension. This validates the feasibility of a safer and easier way to on-line and real-time monitoring of CPA concentration in cell suspension by measuring the EC of waste solution.
机译:在细胞/组织冷冻保存中,应在冷冻后加入冷冻保护剂(CPA)并在解冻后除去。如今人们主要涂抹对CPA去除的离心,这可能导致许多问题。同时,在加工过程中对残留的CPA集中浓度的实时监测简单廉价的方法仍然是未填充的需求。在这项工作中,实施并批准了具有中空纤维透析器的“稀释过滤”系统有效地除去二甲基砜(ME_2SO)。与其他方法(离心和微流体方法)相比,这一人具有低时间和劳动力消耗的优点,对细胞的低渗透损伤,高效性,易于控制最终的悬浮体积和污染风险低。对于CPA添加和细胞悬浮体积控制,还可以容易地修饰“稀释过滤”系统(细胞悬浮体积控制(细胞悬浮液的浓度)。同时,应用了电导率(EC)测量的方法来监测残留的CPA浓度。结果表明废物溶液的EC测量可以在细胞悬浮液中传送CPA浓度。这验证了通过测量废物溶液的EC来验证更安全和更容易的方式和实时监测细胞悬架中的CPA浓度的实时监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号