首页> 外文会议>Conference on Advanced and next-generation satellites >Spectroradiometer focal-plane design considerations: lessons learned from MISR camera testing
【24h】

Spectroradiometer focal-plane design considerations: lessons learned from MISR camera testing

机译:Spectroradiometer Focal-Plane设计考虑因素:从MisR相机测试中汲取的经验教训

获取原文

摘要

The EOS/MISR instrument contains nine cameras; each camera focal plane consists of four closely spaced, linear CCD arrays. Each of the four arrays is preceded by a narrow bandpass filter covering a distinct spectral region. Testing of two engineering model cameras revealed spatial and spectral optical crosstalk levels not predicted by stray light analysis. A detailed investigation of filter coating anomalies and the filter assembly/CCD geometry elucidated several mechanisms responsible for optical crosstalk. These mechanisms, as well as recommendations concerning the design of future focal planes, are presented in this paper.
机译:EOS / MISR仪器包含九个摄像机;每个相机焦平面由四个紧密的线性CCD阵列组成。四个阵列中的每一个在覆盖不同光谱区域的窄带通滤波器之前。两种工程模型相机的测试揭示了杂散光分析未预测的空间和光谱光学串扰水平。对过滤器涂层异常和过滤器组件/ CCD几何形状的详细研究阐明了负责光串扰的几种机制。本文介绍了这些机制以及关于未来联络飞机的设计的建议。