The aim of this study is to demonstrate the technical requirements and performance of fluorescent quantization using image analysis. The quality of fluorescent measurements is largely dependent on the characteristics of instrumentation: fluorescence microscope, low light level camera, fluorescence standard reference, and protocols for image acquisition and measurements calibration. This study is focused on the problem of the efficiency of microscope and low light level cameras. Various types of cameras are tested (SIT C2400-08, intensified CCD C2400-80, and cooled CCD C4880 from Hamamatsu) with respect to stability, linearity, and shading properties. Results show that evaluation of fluorescent instrumentation cannot be reduced to the evaluation of camera properties, the intrinsic evaluation of the fluorescent sample has to be considered as well. Moreover, this work demonstrates the deficiency of usual corrective protocols to lead to reliable quantitative fluorescence analysis.
机译:本研究的目的是展示使用图像分析的荧光量化的技术要求和性能。荧光测量的质量主要取决于仪器的特性:荧光显微镜,低光水平相机,荧光标准参考和图像采集和测量校准的协议。本研究专注于显微镜和低光水平相机效率的问题。关于稳定性,线性度和遮荫特性,测试各种类型的摄像机(坐下C2400-08,加强CCD C2400-80,并从Hamamatsu冷却CCD C4880)。结果表明,荧光仪器的评估不能降低到相机性质的评估,也必须考虑荧光样品的内在评价。此外,这项工作证明了通常的校正方案的缺乏,以导致可靠的定量荧光分析。